This water is then fed into an automatic high-pressure pump on the reverse side of the pre-treatment/control face and then supplied to the reverse osmosis membrane where contaminants are removed from the pressurised feedwater and run to drain.
Purified (permeate) water is then passed into an integrated 150 litre all-plastic storage tank. The tank has a sloping base to allow for complete drainage and a level sensor to automate the RO system and keep the tank filled. Fluid filled stainless steel pressure gauges are fitted to the feedwater pre-filter inlet and outlet to monitor filter differential pressures. The discharge from the RO pump is also fitted with a pressure gauge. Adjustable flow rotameters are also fitted to control reject and recirculated water flow. A non-adjustable flow rotameter is used to monitor permeate flow. RO permeate quality is monitored continuously with an in-line TDS monitor.
Key Features:
- Mixed-bed Deionisation for scavenging trace levels of inorganic contaminants
- Organic scavenger resins or UV photo-oxidation to reduce TOC levels
- UV irradiation to sterilise the water
- Membrane degassing to remove any remaining dissolved gases.
To contact Rotek Australia about Reverse Osmosis Water Treatment System | Deionisation RTA 14-114a use Get a quote.